Environmental
Operating temperature -10ºC to +50ºC
Storage temperature -20ºC to +50ºC
Operating humidity 95% (10ºC to +35ºC) non-condensing
75% (35ºC to +45ºC) non-condensing
Uncontrolled <10ºC
Operating altitude 4,000 m
Storage altitude 12,000 m
Vibration Random 2 G, 5 Hz to 500 Hz
Optical Power Meter (Specifications apply at 23ºC (73ºF), unless otherwise noted.)
Detector type InGaAs
Calibrated wavelengths 850 nm, 1300 nm, 1310 nm, 1550 nm
Measurement range 0 dBm to -50 dBm
Test time 6 seconds
Power measurement linearity ±0.1 dB2
Power measurement uncertainty ±0.35 dB2
Power measurement repeatability < 0.10 dB2
Display resolution, dB or dBm 0.01
Power display units dBm, mW, µW
User-selectable limit for loss 0.05 dB to 50.0 dB, in increments of 0.05 dB up to 10.0 dB and 0.1 dB up to 50.0dB
Auto wavelength detection Yes
Polarity detection Detects A, B, C, and Corning Plug & Play™ Universal Systems polarities
2 kHz detection Yes
Record storage 3000 records, one fiber per record (250 12-fiber cables)
External interface USB 2.0, full speed
Optical connector MPO interface for 12-fiber, unpinned plugs. Compatible with 62.5 µm, 50 µm, and singlemode fibers. Connector has a self-closing, protective cover.
Power requirement 2 AA alkaline batteries
Battery life3 30 hours (typical)
Automatic power-off 10, 20, 30, or 60 minutes (can be disabled by the user)
Low battery warning Low battery icon blinks
Size 5.8 in x 3.2 in x 1.6 in (14.7 cm x 8.0 cm x 4.0 cm)
Weight 10.9 oz (309 g)
  850 nm Source 1310 nm Source 1550 nm Source
Emitter type LED Laser
Wavelength ±30 nm 1310 nm ±20 nm 1550 nm ±20 nm
Spectral width (FWHM) 50 nm (typical) 2 nm typical, 5 nm maximum
Minimum output power ≥ -24 dBm ≥ -1 dBm
Power output stability ≤±0.1 dB over 8 hours4 ±0.25 dB over 8 hours5
Laser safety IEC 60825-1:Class 1
Encircled flux Meets TIA 455-526-14B, ISO/IEC 14763-3, and IEC 61280-4-1 for 50/125 µm at the source’s optical connector. NA
Optical connector MTP/MPO interface for 12-fiber, unpinned plugs. Compatible with 62.5 µm and 50 µm fibers, non-APC only. Connector has a self-closing, protective cover. MTP/MPO interface for 12-fiber, unpinned plugs. Compatible with 9 µm fibers, APC only. Connector has a self-closing, protective cover.

4. 23°C, after 10 minutes of warm-up time.

5. 23°C, after 15 minutes of warm-up time

Modes 2 kHz modulated, auto wavelength/td>
Power requirement 2 AA alkaline batteries
Battery life6 >30 hours (typical)
Automatic power-off 10, 20, 30, or 60 minutes (can be disabled by the user)
Low battery warning Low battery icon blinks
Size 5.8 in x 3.2 in x 1.6 in (14.7 cm x 8.0 cm x 4.0 cm)
Weight 11.4 oz (323 g)

 

  1. For 850 nm, 0 dBm to -50 dBm. For 1300, 1310, 1550 nm, -5 to -50 dBm
  2. Measured power levels ≤0 dBm. Backlight on. Battery life depends on the condition and type of batteries used. Fluke Networks recommends alkaline batteries
  3. 23°C ±2°C, after 10 minutes of warm-up time