MetroScope™ Service Provider Assistant
Specifikace
General Specifications | |
Weight,with battery | 0.86 kg (1.9 lb) |
Dimensions | 19.1 x 15.2 x 4.4 cm (7.5 x 6.0 x 1.75 in) |
Display | LCD touch screen, 640 x 480 pixels, TFT (active) color panel, touch pad |
LED indicators | 6 (including power LED) |
Carrying Case | Rugged carrying case with two removable pockets, camcorder strap and adjustable strand hook |
Power | |
Battery | Lithium Ion 7.2V DC (nominal), 4.2Ah, removable/rechargeable |
Battery life | 4 hour typical, 10 hour in standby mode |
External AC adapter/battery charger | AC input: 90 to 264 V ac, 48 to 62 Hz; 1.5 A |
DC output: 15 V dc, 1.2 A (isolated output) | |
Auto Charger | 12V “cigarette lighter” charger with 6 foot (1.8 m) fully extended coiled cord and LED power indication |
Ports | |
Communication and accessory ports | 1 USB (supports out-of-band NIC for remote control), 1 PCMCIA/Cardbus (PC Card type II), 1 SFP cage, 1 CompactFlash (Card Type I/II), 1 DB-9 serial, headphone jack, microphone jack, Kensington lock receptacle |
RJ-45 / Copper Port | RJ-45 10/100/1000BASE-T Ethernet |
Fiber Port | Small Form-factor Pluggable (SFP) in accordance with MSA |
Supported SFP Modules | 1000BASE- LX, SX, ZX, BX, 100BASEFX |
SFP Connector | Duplex LC |
Environmental and safety | |
Operating Temperature | 0° to +50°C (32° to 122°F) with up to 95% relative humidity |
Battery Charging | 10° to +40°C (50° to 104°F) with up to 95% relative humidity |
Temperature | |
Storage temperature | -20° to +60°C (-4° to 140°F) |
Shock and vibration | Meets requirements of MIL-PRF-28800F for Class 3 equipment |
Safety | CSA Canada and United States, CE, FCC Part
15 Class A, C-TICK N10140; UL and CSA approvals for universal AC
adapter. EMC Complies with EN61326, Class A, Criteria C |
Copper media | |
Cable types | Unshielded twisted pair LAN cables (100 and 120 Ohm UTP) |
Foil-screened twisted pair LAN cables (100 and 120 Ohm ScTP) | |
Cable length | 1 to 305 m (3 to 1000 ft), accuracy dependent upon the cable type selected |
Length resolution | ± [5% of reading + 1 m (3 ft)], with open, shorted, with wire map adapter, or terminated with reflection = 20% |
Receive level | 100 to 5000 mVp-p |
Datalink signal | 500 to 4000 mVp-p |
Measuring terminated cables | The Cable Verification feature tests the individual twisted-pairs of a cable that are terminated into most equipment vendor's Ethernet ports such as on a hub, switch or NIC. All cable tests other than WireView wire map and office locator ID are operational in the presence of datalink signal. |
Wiremapper/office locator compatibility | Detects combinations of shorts, opens, and connector miswires. Compatible with Fluke Networks WireView wire map adapter/office locator. |
Fault tolerance | The RJ-45 Ethernet connection on the analyzer is designed to withstand a maximum of 100 volts. |
Fiber optic power measurements | |
Receive Input Power, Transmit Output Power, Temperature, Voltage, TX Bias Current | Real time access to digital diagnostic monitoring of SFP operating parameters in accordance with the SFP Multi Source Agreement (MSA) and SFF-8472. |
ProVision™ Tests | |
Compatible remote devices | MetroScope, LinkReflector, EtherScope, Physical Loopback, 802.3ah Devices |
Test Configuration | Each test may be made up of an unlimited number of suites which run sequentially. Each suite may measure a maximum of eight streams total (including upstream and downstream) from one to four MetroScope units or a maximum of four streams (roundtrip) from one to four reflectors. |
Test Duration | Each suite can run for any length of time from 1s to 24h. Suites may be run sequentially for virtually unlimited test lengths. |
Tests | Throughput, Latency, Jitter, Loss/BERT, measured in parallel |
Application port | User defined, per stream |
Frame content | All 0s, all 1s, alternating 1s and 0s, Pseudo Random Bit Sequence (PRBS), Incrementing Byte, HFPAT, LFPAT, MFPAT, LCRPAT, SCRPAT |
Frame size | 48, 64, 128, 256, 512, 1024, 1280, 1518, 2024, RFC-2544 sweep, Jumbo sweep, or user-defined including baby jumbo sizes up to 2024 |
Rate (bps) | Up to 1000 MBps (selectable per stream) |
802.1Q settings | VLAN Id, QoS with CoS and ToS , QinQ VLAN Id, priority for each individual stream or all streams. Programmable TPID, DEI, CFI and VID for all streams. |
IP TOS settings | IP Precedence/TOS parameter, DiffServe Code Point |
Pass/Fail Limits | Throughput (separate upstream and downstream), Latency, Jitter, Loss/BERT |
Summary Display | Summary matrix of all streams and all measurements; IP/Mac addresses, VLANPriority/TOS, status,Tx and Rx rates in bps and fps, frames sent and lost, loss ratio, errored intervals; current, average, maximum latency and jitter. |
Detailed Display | Individual measurements may be shown in tabular (by frame size), graphical (by frame size) or trending (by current interfal or total test duration for all frame sizes). |
Frame Loss Statistics | Total, current, and maximum for: frames sent and lost, loss ratio, BER, errored intervals, severely errored intervals |
Data Export | Throughput, Frames Sent/Received, Loss, Delay and Jitter test results for each stream are time stamped and saved to the CD card once per measurement interval for the duration of the test. |
RFC 2544 Tests | |
Compatible remote devices | MetroScope, LinkReflector, EtherScope Layer 1 Loopback, 802.3ah Devices |
RFC-2544 Compliant Tests | Throughput, Latency, Frame Loss, Back-to-Back |
Additional Performance Tests | Jitter, FrameBERT |
Frame content | All 0s, all 1s, alternating 1s and 0s, Pseudo Random Bit Sequence (PRBS), Incrementing Byte , HFPAT, LFPAT, MFPAT, LCRPAT, SCRPAT |
Frame size | 48, 64, 128, 256, 512, 1024, 1280, 1518, RFC-2544 sweep, Jumbo sweep, or user-defined including baby jumbo sizes up to 2024 |
Application port | User defined |
Rate (bps) | Up to 1000 Mbps |
802.1Q settings | VLAN Id, priority |
IP TOS settings | IP Precedence/TOS parameter, DiffServe Code Point |
Throughput settings | Duration, maximum rate, measurement accuracy, pass/fail limits |
Latency settings | Duration, rate, iterations, pass/fail limits |
Frame loss settings | Duration, rate, step size, pass/fail limits |
Frame loss settings | Duration, rate, step size, pass fail |
Back to Back settings | Min and Max duration, rate, iterations, pass/fail |
Jitter Settings | Duration, rate, pass/fail |
FrameBERT Settings | Duration, rate, pass/fail |
Traffic generator | |
Traffic type | Broadcast, multicast or unicast |
Frame type | Benign Ethernet, Benign LLC, NetBEUI, Benign IP, IP/ICMP Echo, IP/UDP Echo, IP/UDP Discard, IP/UDP Chargen, IP/UDP NFS, IP/UDP NetBIOS , Layer 1/2/3 BERT |
Frame size | 48 , 2024 bytes (48,2024) |
Rate | Utilization (%): 0.1 – 100, Frames/second: 1 – 1488095 |
Duration | Seconds: 1 – continuous, Frames: 1 – continuous |
FCS Error | Generates any frame setting with an FCS error |
Background mode | May be run concurrent with all other MetroScope tests excluding ProVision and RFC 2544 tests. |
802.3ah Client | |
Functions | Remote device discovery, loop-up with 1s keep-alive, loop down. May be run in background while other MS functions are active. |
Display | Loopback capability of remote, OAM status OAM mode link status, maximum OAM size, remote state |
IPTV Tests | |
Configuration | Multicast Group IP, Port Number, join, leave, RTSP URL, setup, play, pause, teardown |
Results | IGMP Latency, Total Packets Sent, Connected Time, Received Packet Rate, RFC-4445 MDI Delay Factor and Media Loss Rate for MPEG-2 streams |
Service Performance Tool | |
Category of devices tested | DHCP Servers, DNS Servers, E-mail Servers (SMTP, POP3), NT File Servers, Web Servers, WINS Servers, User-Defined Servers |
Test controls | Iterations, interval |
Add device by | IP address or host name (except Web Server where URL added) |
DHCP Server pass/fail criteria | Ping response time, server response time |
DHCP Server BOOTP parameters (optional) | Subnet mask, domain server, WINS server, NetBIOS scope, POP3 server, router/default gateway, client DNS domain, NetBIOS node type, SMTP server, web server |
DNS Server pass/fail criteria | Ping response time, server response time |
E-mail Server pass/fail criteria | Ping response time, SMTP SYN/ACK response time, SMTP response time, POP3 SYN/ACK response time, POP3 response time |
E-mail Server operation modes | Connect only, log in only, send/receive |
NT File Server pass/fail criteria | Ping response time, SYN/ACK response time, connect time |
NT File Server operation modes | Server response, read, write/read/delete |
Web Servers pass/fail criteria | Web Server name lookup time, ping response time, SYN/ACK response time, first reply time, receive time, receive rate |
WINS Servers pass/fail criteria | Ping response time, server response time |
User-Defined Servers pass/fail criteria | Ping response time, SYN/ACK response time |
Results format | Tabular, graphical, xml-based report |
Wireless LAN Adapter Option | |
Specification compliance | IEEE 802.11a, 11b, 11g |
Certifications | FCC part 15, Telec, CTICK, ETSI, EN301893, EN60950 |
Interoperability | WECA Compliant |
Interface | 32-bit Cardbus |
Outdoor operating range | Up to 515 m (1690 ft) |
Indoor operating range | Up to 85 m (279 ft) |
Data rate | 802.11a: up to 54 Mbps, 802.11b: up to 11 Mbps, 802.11g: up to 54 Mbps |
Output power | 18 dBm peak power |
Infrastructure mode | BSS |
External antenna connector jack | Hirose MS-147 |
Wireless LAN Directional Antenna | |
Frequency range | 2.4 – 2.5 and 4.9 - 5.9 GHz |
Minimum gain | 5.0 dBi in the 2.4 GHz band and 7.0 dBi in the 5 GHz band |
External antenna connector plug | Hirose MS-147 |
VoIP Phone Option | |
Calling Modes | SIP Call Manager, Direct IP Address |
Address Book | Stores complete settings for up to 99 destinations |
WAV File Output | Play 1-30 times or continuous |
Settings | Call Manager Registration (Username, Password, Registrar, Proxy); NAT (Server); RTP (Codec and Port); Answer Control (Auto, Wave File, Do Not Disturb); |
Call Log | ASCII log of all major call events |
Measured Results | Total, current, maximum and minimum for: Frames Received and Dropped, MOS, R-Factor, Latency |
Trend Graphs | MOS, R-Factor, Latency Graph with user-selectable update interval of 5s, 10s, 1 min, 10 min, 1 hour |
LinkReflector specifications | |
Weight | 10 oz (311 grams) with batteries installed |
Dimensions | 5.3” h x 3.1” w x 1.3” d (13.46 cm x 7.87 cm x 3.30 cm) |
Operating Temperature | 10° to +40°C (50° to 104°F) with up to 95% relative humidity |
Media Access | 10BASE-T, 100BASE-TX, 1000BASE-T (IEEE 802.3), and PoE (IEEE 802.3af) |
Operating Modes | Reflect All, Reflect Targeted MAC, Reflect Targeted IP, Reflect Fluke Networks Test Traffic, Reflect Non-Broadcast, Non-Reflecting (Troubleshooting Mode) |
Address Setting | Manual or DHCP |
LinkReflector Troubleshooting Mode | |
Cable Tests | Pair lengths, opens, shorts, splits, crossed, straight through, and cable ID |
Tone Generator | IntelliTone digital tone: [500 KHz]; analog tones: [400Hz, 1KHz] |
Ping | Automatically pings default router and DNS server; can be configured to ping up to 10 additional devices. |
802.1x | Discovers and gains authentication to 802.1x networks. |
PoE Detection | Detects and identifies PoE type. |
Port Verification | Displays make, model, address, slot, and port of the nearest LLDP device |
User Interface (UI) | Display: black and white, 2” x 1” display, link LED; control: five push-buttons for selection of icons and navigation of menus; power: on/off button |
Ports | Test ports: RJ45 ports (2): network test port, loop-back wire map port; Application port: mini-USB, Kensington lock receptacle |
Power Source | 4 AA batteries or optional Li-ion Battery Pack with AC Charger |