Specifikace Fiber QuickMap

Specifikace

Models
Operating temperature with the battery 0ºC to 50ºC
Non-operating temperature -20ºC to 60ºC
Operating relative humidity (without condensation) 95% (10ºC to 35ºC) 75% (35ºC to 40ºC) uncontrolled < 10ºC
Vibration Random, 5 Hz to 500 Hz, MIL-PRF-28800F CLASS 2
Shock 1 meter drop test
Altitude 3000m
EMC EN 61326-1: 2004
Battery type 2 AA alkaline batteries (no battery charger)
Battery life 1500 tests (typical)
Laser safety Class 1 CDRH Complies to EN 60825-2
LCD type Backlit black and white (segments)
Index of refraction range 1.45 to 1.5 (factory default is 1.496)
Auto turn off Automatically turns off after 5 minutes if no keys are pressed. Backlight turns off first.
Factory calibration interval None
Output wavelengths 850 nm ± 10 nm
Laser classification Class 1 CDRH Complies to EN 60825-2
Dynamic range >11 dB
Maximum distance 1500 meters or 4921 feet
Maximum number of incidents shown 9
Distance accuracy (0 m to 1500 m or 0 ft to 4921 ft) ± (1 m + 0.1 % x length) for reflective incidents1 ± (3 m + 0.1 % x length) for non-reflective incidents2
Testing speed < 6 seconds typical
Connector Removable/cleanable SC adapter, UPC polish
Fiber types tested 50/125 µm or 62.5/125 µm multimode
Detection of reflective incidents3 -35 dB default threshold (User selectable: -20 dB to -45 dB in 5 dB increments)
Reflectance accuracy4 ± 4 dB
Maximum reflectance measurement -20 dB
Detection of loss incidents5 0.70 dB default threshold (user-configurable from 0.5 dB to 6.1 dB in 0.2 dB increments)
Bulkhead quality If no fiber is attached or if the connector is dirty, the troubleshooter displays 0 m or 0 ft.
Live fiber detection Detects optical signals from 600 nm to 1050 nm and shows ACTIVE LINE if a signal is there. Looks for a signal every 3 seconds after the first detec-tion. +7 dB maximum input power.
Certifications and compliance     Conforms to relevant European Union
                directives
    Conforms to relevant Australian standards
   Listed by the Canadian Standards Association CSA
               C22.2 No. 61010.1.04
   Conforms to FCC Rules, Part A, Class A

 

1. ± user-configurable Index of Refraction (IOR) error ± the incident location error. Incident location error for reflective incidents: ±1 m from 1 m to 1.5 km.
2. ± user-configurable Index of Refraction (IOR) error ± the incident location error. Incident location error for non-reflective incidents: ±2 m for lengths £15 m, otherwise ±1 m.
3. Finds and gives the location of an incident that has a reflectance larger than -55 dB. Detects incidents >1m after the bulkhead connector when the bulkhead reflectance is <35 dB. Detects incidents >3 m after an incident when the incident reflectance is <35 dB.
4. With a backscatter coefficient of -63 dB at 850 nm using a calibrated -14 dB reference.
5. Detects incidents >10 m after the bulkhead connector or any prior incident when the bulkhead reflectance is <-35 dB and the reflectance of any prior incident is <-35 dB. The maximum link loss prior to the incident is <7 dB.


© FLUKETESTERY.CZ Všechna práva vyhrazena.

created by hotpotato – xhtml & css valid, use Mozilla – the best browser available | Fluke Networks

Informace o cookies | Informace o ochraně osobních údajů